COMPU-SHACK PRODUCTION, GMBH

CS-ARCNET-KARTE (REV. 3.31/3.31S)

NIC Type:

ARCnet

Transfer Rate:

2.5Mbps

Data Bus:

8-bit ISA

Topology:

Linear Bus

Wiring Type

RG62A/U 93ohm coaxial

Boot ROM

Available

INTERRUPT SELECT - J2

IRQ

Jumper A

Jumper B

Jumper D

Jumper D

Jumper E

»

IRQ2

Closed

Open

Open

Open

Open

 

IRQ3

Open

Closed

Open

Open

Open

 

IRQ4

Open

Open

Closed

Open

Open

 

IRQ5

Open

Open

Open

Closed

Open

 

IRQ7

Open

Open

Open

Open

Closed

RESPONSE TIME-OUTS

Response Time

J4/jumper A

J4/jumper B

»

74.7µs

Open

Open

 

283.4µs

Closed

Open

 

561.8µs

Open

Closed

 

1118.6µs

Closed

Closed

I/O ADDRESS

Address

S1/1

S1/2

S1/3

S1/4

S1/5

S1/6

2E0h

Off

On

Off

Off

Off

On

200h

Off

On

On

On

On

On

210h

Off

On

On

On

On

Off

220h

Off

On

On

On

Off

On

I/O ADDRESS

Address

S1/1

S1/2

S1/3

S1/4

S1/5

S1/6

230h

Off

On

On

On

Off

Off

240h

Off

On

On

Off

On

On

250h

Off

On

On

Off

On

Off

260h

Off

On

On

Off

Off

On

270h

Off

On

On

Off

Off

Off

280h

Off

On

Off

On

On

On

290h

Off

On

Off

On

On

Off

2A0h

Off

On

Off

On

Off

On

2B0h

Off

On

Off

On

Off

Off

2C0h

Off

On

Off

Off

On

On

2D0h

Off

On

Off

Off

On

Off

2F0h

Off

On

Off

Off

Off

Off

300h

Off

Off

On

On

On

On

310h

Off

Off

On

On

On

Off

320h

Off

Off

On

On

Off

On

330h

Off

Off

On

On

Off

Off

340h

Off

Off

On

Off

On

On

350h

Off

Off

On

Off

On

Off

360h

Off

Off

On

Off

Off

On

370h

Off

Off

On

Off

Off

Off

380h

Off

Off

Off

On

On

On

390h

Off

Off

Off

On

On

Off

3A0h

Off

Off

Off

On

Off

On

3B0h

Off

Off

Off

On

Off

Off

3C0h

Off

Off

Off

Off

On

On

3D0h

Off

Off

Off

Off

On

Off

3E0h

Off

Off

Off

Off

Off

On

3F0h

Off

Off

Off

Off

Off

Off

MEMORY ADDRESS

Address

S1/7

S1/8

S1/9

S1/10

C0000h

Off

Off

On

On

D0000h

Off

Off

On

Off

E0000h

Off

Off

Off

On

NODE ID NUMBER

ID #

S2/1

S2/2

S2/3

S2/4

S2/5

S2/6

S2/7

S2/8

1

On

Off

Off

Off

Off

Off

Off

Off

255

On

On

On

On

On

On

On

On

Note:Nodes can be numbered from 1 to 255. The switches are a binary representation of the node numbers. When a switch is on, the corresponding bit is set to 1 and has the following decimal value: S2/1=1, S2/2=2, S2/3=4, S2/4=8, S2/5=16, S2/6=32, S2/7=64, S2/8=128.

DIAGNOSTIC LED

Status

Condition

On

Data is being transmitted or received

Off

Data is not being transmitted or received