M A B - 3 0 9 1 S C A L 4 FUJITSU Native| Translation ------+-----+-----+----- Form 3.5"/SLIMLINE Cylinders 8490| | | Capacity form/unform 9120/ MB Heads 10| | | Seek time / track 8.0/ 1.0 ms Sector/track | | | Controller SCSI3 SI/WI/FA/SCA2 Precompensation Cache/Buffer 496 KB PROGRAMMABLE Landing Zone Data transfer rate MB/S int Bytes/Sector 512 40.000 MB/S ext SYNC Recording method PR4ML operating | non-operating -------------+-------------- Supply voltage 5/12 V Temperature *C 5 50 | -10 60 Power: sleep W Humidity % 20 80 | 20 80 standby W Altitude km 3.000| 12.000 idle W Shock g 5 | 60 seek W Rotation RPM 7200 read/write W Acoustic dBA spin-up W ECC Bit ON THE FLY,REED SOLOMON MTBF h 1000000 Warranty Month Lift/Lock/Park YES Certificates ********************************************************************** L A Y O U T ********************************************************************** FUJITSU MAA-3182/MAB-3045/3091SC/SP JUMPER SETTING +---------------------------------------------------------+ | | | |XXI | |XXN | |XXT | |XXE | 1---+ |XXR | +---6 |XXF | CN6 |XXA | |XXC | |XXE | |XX | |XX | |XX | | | SC Models | +---------------------------------------------------------+ SP Models --------- +2-+4-+6-+ | |XX|XX| +1-+3-+5-+ | | +--- SCSI terminating resistor | +------ Motor start mode - activated when power supplied +--------- Setting terminal power supply +2-+4-+6-+8-+10+12+14+16+ |XX|XX|XX|XX| | | | | +1-+3-+5-+7-+9-+11+13+15+ | | | | | | | +-- LED signal | | | | | | +------ Write protect - enabled | | | | | +--------- HDD Reset signal | | | | +------------ Spindle Sync Pulse signal | | | +--------------- SCSI ID+ | | +------------------ SCSI ID+--SCSI ID 15 | +--------------------- SCSI ID+ +------------------------ SCSI ID+ ********************************************************************** J U M P E R S ********************************************************************** FUJITSU MAA-3182/MAB-3045/3091 SWITCH SETTINGS Setting Terminals ----------------- The user must set the following terminals and SCSI terminating resistor before installing the HDD in the system. Setting terminal: CN6 Notes: 1. The user must not change the setting of terminal not described in this section. Do not change setting status set at factory shipment. 2. Do not change the setting of terminals except following setting pins during the power is turned on. - Write protect MAx3xxxSP: CN7 13-14 3. To short the setting terminal, use the short plug attached when the device is shipped from the factory. SCSI ID setting SCA type 16-bit SCSI model (MAx3xxxSC) -------------------------------------- There is no SCSI ID setting terminals for SCA type model. Set the SCSI ID using ID0,ID1,ID2, and ID3 signals on the SCSI interface connector (CN1). Single-ended 16-bit SCSI model (MAx3xxxSP) ------------------------------------------ IMPORTANT When the SCSI ID is set using the external operator panel connector CN1, all pins listed in Table 1 should be open. If any of pins are shorted, unexpected SCSI is set. IMPORTANT 1. Set the SCSI ID so that there are no duplicates between SCSI devices on the same SCSI bus. 2. The priority of SCSI bus use in ARBITRATION phase is determined by SCSI ID as follows: 7>6>5>4>3>2>1>0>15>14>13>12>11>10>9>8 SCSI ID SP Models TABLE 1 ----------------- +----------+-------------------------------+ | SCSI ID | Jumper Location | | | PINS | | | 7-8 | 5-6 | 3-4 | 1-2 | +----------+-------+-------+-------+-------+ | 0 | OPEN | OPEN | OPEN | OPEN | +----------+-------+-------+-------+-------+ | 1 | OPEN | OPEN | OPEN | CLOSED| +----------+-------+-------+-------+-------+ | 2 | OPEN | OPEN | CLOSED| OPEN | +----------+-------+-------+-------+-------+ | 3 | OPEN | OPEN | CLOSED| CLOSED| +----------+-------+-------+-------+-------+ | 4 | OPEN | CLOSED| OPEN | OPEN | +----------+-------+-------+-------+-------+ | 5 | OPEN | CLOSED| OPEN | CLOSED| +----------+-------+-------+-------+-------+ | 6 | OPEN | CLOSED| CLOSED| OPEN | +----------+-------+-------+-------+-------+ | 7 | OPEN | CLOSED| CLOSED| CLOSED| +----------+-------+-------+-------+-------+ | 8 | CLOSED| OPEN | OPEN | OPEN | +----------+-------+-------+-------+-------+ | 9 | CLOSED| OPEN | OPEN | CLOSED| +----------+-------+-------+-------+-------+ | 10 | CLOSED| OPEN | CLOSED| OPEN | +----------+-------+-------+-------+-------+ | 11 | CLOSED| OPEN | CLOSED| CLOSED| +----------+-------+-------+-------+-------+ | 12 | CLOSED| CLOSED| OPEN | OPEN | +----------+-------+-------+-------+-------+ | 13 | CLOSED| CLOSED| OPEN | CLOSED| +----------+-------+-------+-------+-------+ | 14 | CLOSED| CLOSED| CLOSED| OPEN | +----------+-------+-------+-------+-------+ | 15 | CLOSED| CLOSED| CLOSED| CLOSED| Factory shipment +----------+-------+-------+-------+-------+ Each mode setting ----------------- SP Models - Setting terminal power supply ----------------------------------------- CN6 Pin 1-2 OPEN Supply off CLOSED Supply on (Default) SP Models - Motor start mode ----------------------------- Set how to control the starting of the HDD spindle motor. This setting only determines the operation mode when the power supply is turned on or microcode is downloaded. In both modes, stopping or restarting the spindle motor can be controlled by specifying the START/STOP UNIT command. This setting is not provided for SCA-2 type 16-bit SCSI model (MAx3xxxSC). CN6 Pin 3-4 OPEN Starting motor is controlled with START/STOP UNIT Command. CLOSED The motor is started immediately after the power supply is turned or the microcode is downloaded. (Default) Write Protect ------------- When the write protect function is enabled, writing to the disk medium is disabled. The write protection funtion setting is not provided to the SCA type 16-bit SCSI model (MAx3xxxSC). ---------------------+--------------------+-------------------------+ MAx3xxxSS CN7 11-12 |MAx3xxxSP CN7 13-14 | DEFAULT | OPEN | OPEN | Write operation enabled | ---------------------+--------------------+-------------------------+ CLOSED | CLOSED| Write operation disabled| ---------------------+--------------------+-------------------------+ Connection of terminating resistor on SCSI interface ---------------------------------------------------- SCA-2 type 16-bit SCSI model (MAx3xxxSC) ---------------------------------------- Since there is no SCSI terminating resistor on the SCSI interface for SCA-2 type 16-bit SCSI, there is no setting on the HDD. Single-Ended 16-bit SCSI model (MAx3xxxSP) ------------------------------------------ Setting terminals CN6 5-6 whether to use the terminating resistor circuit on the SCSI interface provided for the HDD. IMPORTANT When the external operator panel is connected using the external operator panel connector CN1, this setting only wheen A9 pin (DISCON) is open. MAx3xxxSP CN6 5-6 OPEN Terminating resistor circuit is not connected. CLOSED Terminating resistor circuit is connected. Default Mode settings ------------- In addition to the previously described settings using setting terminals, the Hdd is provided several mode settings. The mode settings are enabled by specifying the CHANGE DEFINITION COMMAND. Default mode settings +--------------------------------------------------+----------------+ |SCSI level |SCSI-2 | +--------------------------------------------------+----------------+ |SYNCHRONOUS DATA TRANSFER REQUEST message sending |Sent from HDD | +--------------------------------------------------+----------------+ |UNIT ATTENTION report mode |Reported | +--------------------------------------------------+----------------+ |Reselection retry count |Not restricted | +--------------------------------------------------+----------------+ |WIDE DATA TRANSFER REQUEST message sending |Sent from HDD | +--------------------------------------------------+----------------+ |Reselection time-out delay |250 ms | +--------------------------------------------------+----------------+ |Spindle motor start delay time |0 sec | +--------------------------------------------------+----------------+ ********************************************************************** I N S T A L L ********************************************************************** -ANY DIREC. Notes on installation ===================== Installation direction ---------------------- horizontally vertically +-----------------+ +--+ +--+ | | | +-----+ +-----+ | | | | | | | | | +-+-----------------+-+ | | | | | | +---------------------+ | | | | | | | | | | | | | | | | | | +---------------------+ | +-----+ +-----+ | +-+-----------------+-+ +--+ +--+ | | | | +-----------------+ The drive will operate in all axis (6 directions).